Product detail

ZGR FAA / AHF
ACTIVE HARMONIC FILTER

ZGR FAA / AHF

ZGR FAA / AHF is a system that helps to eliminate harmonic distortion in the power grid.

Request information

Characteristics

The ZGR FAA / AHF helps to eliminate harmonic contamination in the grid, reducing power quality problems and enhancing a more efficient and safe use of energy.

The presence of harmonics increases the RMS current in electricity grids. The transmission of currents harmonics through system impedance creates harmonics which produce voltage distortions and in this way deteriorate the quality of the grid voltage. This leads to increased operation and energy costs, production/process stops, overheating and malfunctioning of electrical equipment.

The ZGR FAA / AHF is designed according to the latest state of the art in power electronics technology.

The technology is installed in parallel with non-linear electrical loads. The active filter analyses the phase current together with the associated harmonics, generating a compensation current, which neutralizes the harmonic currents creating a practically sinusoidal waveform.

TECHNICAL SHEET
  • High security and reliability
  • Harmonic compensation up to the order of 50º (individually selectable)
  • Flicker Compensation
  • Ultra-fast reactive power compensation (inductive and capacitive)
  • Phase and neutral cable balance
  • Compact design
  • Scalable modular system (25A - 600A)
  • Resonance detection
  • Digital control with intelligent FFT algorithm
  • Ethernet and Ethercat connection system
  • High performance and reliability
  • Insensitive to grid conditions
  • Protections: Overload protection; Internal short circuit protection; Over temperature protection; Over and under voltage protection; Inverter bridge; Resonance protection; Fan failure alarm

Technical sheet

TECHNICAL SPECIFICATIONS
Model ZGR FAA / AHF
Nominal voltage 380 V (228 a 456 V) 480 V (384 a 552 V) 690 V (480 a 790 V)
Frequency 43 – 62 Hz
Compensation current (module) 25 A, 35 A, 50 A, 60 A, 100 A, 150 A 75 A, 90 A 75 A, 90 A
Compensation capacity in neutral terminal 3 times the compensation current (in case of 4 wire system)
Compensation range of harmonic currents 2nd - 50th harmonic order, or specified order of harmonics 0 - 110%
Harmonic reduction rate > 95%
Power factor (PF) Adjustable from -1 to 1
Switching frequency/control 20 kHz / 20 kHz
Reaction time < 50 µs
Global response time < 5 ms
Harmonic compensation Yes
Reactive power compensation Yes
Unbalance compensation Yes
MONITORING
Screen TFT 7’’ colour
Communication ports RS485, network port (RJ45)
Communication protocols Modbus RTU, TCP/IP (Ethernet)
PROTECTIONS
Failure alarm Yes, 500 alarm logs max.
Protections Overvoltage, under voltage, short-circuit, inverter bridge, over compensation
MECHANICAL AND ENVIRONMENTAL CHARACTERISTICS
Working temperature range -10 ºC ~ +40 ºC (without derating)
Protection degree IP20
Working altitude 1500 m (without power loss)
Noise leve < 56 dB (depending on the model) < 65 dB (depending on the model)
Relative humidity 5 to 95% (without condensation)
Cooling Forced
STANDARDS
Certifications CE, IEEE 61000 CE, ETL (UL508), IEEE 61000
Standards IEEE 519, ER G5/4

Operations manual

Hybrid, robust and reliable solutions

REQUEST FURTHER INFORMATION

If you want to know if you can purchase a product from the Zigor catalogue, you have questions on the operation and/or composition or simply want to know more about the Zigor products, leave your details and we will contact you. Furthermore, if you wish, you can download the complete catalogue by clicking on the button below.

DOWNLOAD 2024 CATALOGUE

    PRODUCT INFORMATION

    Leave your details and we will contact you to answer your questions.

    privacy policy

    Solutions that inspire

    All the success stories