Product detail

Professional

ZGR INFLUENCE HP 50-200

ONLINE THREE-PHASE UPS

Available from 50 to 200 kVA (PF 1).

ZGR INFLUENCE HP advanced three-phase technology (3:3), with efficiency up to 95.5% and independent bypass input.
Model for fully customisable autonomies with external battery cabinets.

Allows paralleling of up to 4 units natively without additional electronic cards.

Request information

Characteristics

ZGR INFLUENCE HP expands options with a range from 50 kVA to 200 kVA and improves its technology with a 3-stage inverter, which results in a lower power
loss in conversion and achieves an efficiency of up to 95,5 %.
Great efficiency for this series of small UPS.
In this power range, ZGR INFLUENCE HP offers an FP 1,0 for your consumption which makes it suitable for all types of installations that demand high energy
quality and seek the best energy efficiency.
It is an ideal equipment to protect industrial processes, hospitals, data centers, transportation, emergencies and security.
They are available in Dual input version that allows a three-phase auxiliary bypass grid.

TECHNICAL SHEET
  • 3:3 and optional double input
  • Efficiency of 95,5 %
  • Parallelable up to 4 units
  • Possibility of sharing same batteries in parallel equipment
  • Compatible with NiCd / Li (on request)
  • Online double conversion with DSP control
  • Low current distortion
  • Possibility of long autonomies
  • Compatible with generators sets
  • Configurable battery voltage
  • Cold Star and Auto Restart function
  • Integrated input/output/bypass MCB protections
  • Double conversion online (Rectifier/Inverter) • Completely insulates the consumption of voltage, frequency and noise variations from the power grid
  • ECO function • Minimizes UPS’s self-consumption and improves performance
  • Communications • 2 independent bays for smart cards and dry contacts alarms • Communication software included
  • Grid Backup Function • Allows 2 groups in parallel with 2 independent three-phase grids

Technical sheet

TECHNICAL SPECIFICATIONS
Model INFLUENCE HP 50 INFLUENCE HP 60 INFLUENCE HP 80 INFLUENCE HP 100 INFLUENCE HP 120 INFLUENCE HP 150 INFLUENCE HP 200
Power 50kVA / 50kW 60kVA / 60kW 80 kVA / 80 kW 100kVA / 100kW 120kVA / 120kW 150kVA / 150kW 200 * Consultar kVA / 200kW
Power factor 1,0
Format Tower / Cabinet
INPUT ELECTRICAL CHARACTERISTICS
Voltage range 305 - 485 Vac (allows use with generators) 3 phases + N + PE
Frequency 40 - 70 Hz (auto detecting)
Power factor 0,99
THDi (100 % load) < 3 % non linear
OUTPUT ELECTRICAL CHARACTERISTICS
Nominal voltage 380 / 400 / 415 Vac (3 phases + N + PE) ± 1 %
Frequency (battery mode) 50 / 60Hz ± 0,1Hz
Waveform (battery mode) Pure sinewave
THD harmonic distortion (100 % load) < 1 % linear / < 3 % non linear
Transfer time 0 ms battery / 0 ms bypass
Permissible peak current 3:1
Overcharge (Online) <110% -60 min. / <125% -10 min. / 150% 1 min. * Check
EFFICIENCY
Inverter mode Up to 96%
BATTERY
Maximum charger current 20 A 40 A 60 A
DC bus voltage 384 - 600 Vdc
Temperature sensor External sensor (optional)
Autonomy Customizable from 5 minutes to several hours (depends on the battery capacity)
MONITORING
Informative 7’’ colour TFT touch screen
Alarms Acoustics depending on alarm (optional potential-free contacts)
Software Windows
CONNECTIONS
Terminal panel Input / Output / Bypass / Battery
Protection switch Input / Output / Bypass
Bypass Maintenance switch (MCB) 100 A 125 A 200 A 200 A 250 A 320 A 320 A
Bypass input (Dual input) Yes (principal + bypass)
Communication USB / RS232 / RS485 (no simultaneously)
Intelligent port 2 bays (optional SNMP / optional dry contact)
FUNCTIONS
On/OFF with battery (Cold Start) Yes (allows UPS to run without mains power)
Auto Restart Yes (restarts UPS functions after a failure or deep battery discharge)
ECO mode Yes
Emergency Power Off function (EPO) Rear panel terminals
Parallelable Yes (up to 4 units)
Master/Slave function (LBS) It enables grouping parallels Master / Slave and control the network switch (STS)
Bypass operation limits Configurable
Frequency converter 50 - 60Hz Yes
ENVIRONMENTAL AND MECHANICAL CHARACTERISTICS
Cooling Forced with fans (PWM speed control)
Operation temperature 0 -40 ºC
Noise level (at 1 m) < 58dB < 60dB < 61dB < 63dB < 63dB < 66dB < 68dB
Relative humidity 0 - 95 % without condensation
Dimensions (WxHxL) 250 x 868 x 828 mm 442 x 1200 x 850mm 442 x 1200 x 850 mm
Weight approx. 80 kg 82 kg 144 kg 147 kg 155 kg 190 kg 230 kg
STANDARDS
Marking CE
Directives Low voltage directive: 2014/35/EU, EMC directive: 2014/30/EU040-3
Standards Safety: EN 62040-1, EMC: EN 62040-2, Accordance: EN 62040-3

Documents

User manual

Datasheet

Pictures

Hybrid, robust and reliable solutions

REQUEST FURTHER INFORMATION

If you want to know if you can purchase a product from the Zigor catalogue, you have questions on the operation and/or composition or simply want to know more about the Zigor products, leave your details and we will contact you. Furthermore, if you wish, you can download the complete catalogue by clicking on the button below.

DOWNLOAD 2023 CATALOGUE

    PRODUCT INFORMATION

    Leave your details and we will contact you to answer your questions.

    privacy policy

    Solutions that inspire

    All the success stories